Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int. j. morphol ; 41(4): 1101-1106, ago. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1514325

RESUMO

La investigación tuvo como objetivo determinar la influencia de la morfología externa de la raíz de primeros premolares superiores en la existencia de sobreestimación radiográfica durante la preparación para poste. Con este fin se realizó un estudio transversal in vitro, donde 60 premolares superiores uniradiculares fueron instrumentadas con fresas Gates Glidden y Pesso de calibre 1, 2 y 3. Seguidamente se obtuvieron imágenes radiográficas digitales de cada pieza dentaria mediante un aparato posicionador a una distancia constante en sentido vestíbulo lingual, asimismo se realizaron imágenes tomográficas volumétricas de las muestras. En ambas técnicas imagenológicas se midió el espesor a mesial y distal de las piezas. La sobreestimación fue calculada mediante la diferencia de la medida tomográfica menos la radiográfica. Los resultados indicaron que en ambas paredes radiculares hubo diferencia significativa entre las medidas radiográficas y tomográficas (p<0,05), encontrándose en la pared distal diferencias altamente significativas (p<0,001); además se evidenció que la sobreestimación radiográfica fue mayor en la pared distal. El estudio concluyó que existe sobreestimación radiográfica en premolares superiores durante la preparación para poste de un 20,42 % en promedio, siendo la pared distal la estructura que presenta mayor sobreestimación.


SUMMARY: he investigation´s objective was to determine the influence of external morphology of the root of upper first premolars in the existence of radiographic overestimation during preparation for post. An in vitro cross-sectional study was carried out, where 60 single-rooted upper premolars were instrumented with burs. Gates Glidden and Pesso of caliber 1, 2 and 3, then, digital radiographic images of each dental piece were obtained by means of a positioning device at a constant distance in the buccolingual direction; volumetric tomographic images of the samples were also performed. In both imaging techniques, the mesial and distal thickness of the pieces was measured. The overestimation was calculated by the difference of the tomographic measurement minus the radiographic one. The results indicated that in both root walls there was a significant difference between the radiographic and tomographic measurements (p<0.05), with highly significant differences being found in the distal wall (p<0.001); In addition, it was evidenced that the radiographic overestimation was greater in the distal wall. The study concluded that there is radiographic overestimation in upper premolars during post preparation of 20.42% on average, with the distal wall being the structure that presents the greatest overestimation.


Assuntos
Humanos , Dente Pré-Molar/diagnóstico por imagem , Preparo do Dente , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Dente Pré-Molar/anatomia & histologia , Intensificação de Imagem Radiográfica , Estudos Transversais , Técnica para Retentor Intrarradicular , Preparo de Canal Radicular , Cavidade Pulpar/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...